Tag Archives: magnetic field

EMF Testing Indoor Air Quality Radon Gas Testing: 214.912.4691 Dallas – Houston – Austin – Fort Worth

Powerline Home Safe Distance Cell Phone RF Surveys

Cell Tower Site on High Voltage Power Line near homes in residential area in North Dallas – EMF Testing and Surveys

EMF Testing / Magnetic Field Survey & Safe Distance Measurement Services

EMF testing for those concerned about living near powerlines and feeders is available for commercial clients and limited residential with reports that range from verbal to complete reports with photo documentation and graphics. We also provide consultation on viable strategies and products for EMF protection. We travel all over Texas and cities in adjacent states including Dallas, Houston, Fort Worth, Austin, San Antonio and Oklahoma City.

RF (Radio Frequency) Scans and Evaluations – Maximum Permissible Exposure (MPE)

We test RF energy for frequency and amplitude in order to find sources and evaluate safety with respect to FCC regulatory, compliance and precautionary guidelines, and to determine potential interference issues between wireless routers, cell phone repeaters / boosters, Radio Frequency Identification (RFID) systems, and wireless microphone / audio / video data systems.

Magnetic / Electric / RF & EMF Shielding Consultations including proper grounding

If you have an issue with electromagnetic energy that is either a safety issue or causes equipment interference, we are fully qualified to assess, troubleshoot and make sound recommendations to fix or mitigate the situation.

Radon Gas Measurements & Surveys (Short / Long Term Testing)

With a background in radon and radiation safety, we are capable of evaluating and reporting on radon gas levels, how they compare with EPA standards and whether a mitigation solution is called for.

EMF Testing for Electrical Wiring Issues Indicated by Excessive EMF Fields

Whether you believe in the safety hazards of EMF or not, the most common source of high EMF fields inside the home is improper wiring which fails to conform to current NEC code. ScanTech can detect and direct repairs on electrical wiring that manifests as an abnormal magnetic field.

Preliminary Construction Surveys / Property Transfer Phase I Environmental Site Due Diligence Survey testing regarding Indoor Air Quality (IAQ) – EMF Consultation for Safety and potential EMI – Radon Testing for Multi-Family Dwellings and Commercial Buildings.

We are often called out to site before a structure or complex is erected in order to survey and communicate any possible issues and the potential impact of nearby power lines, substations, transformers, cell towers and other EMF/RF generating sources. We also make construction recommendations for minimizing electromagnetic field emissions for safety and electromagnetic Interference concerns with sensitive manufacturing and research equipment.

Indoor air quality testing for VOC levels regarding Certificate of Occupancy permits according to City of Dallas Green Ordinances. Also known as the 804.2 Post-Construction, Pre-Occupancy Baseline IAQ Testing which is a 4 hour test for 500 uG / m^3 or less of VOCs.

Magnetized & Radiation Contaminated Metals, Stone and Imported Products

ScanTech has been in the radiation survey business for over 10 years and is routinely called upon to investigate cases of suspected radioactive contamination and magnetized ferrous metals which can cause unusual issues. Our instrumentation includes several Geiger counters with capable of detecting Alpha and Beta particle emissions, X-Rays and includes specialized Gamma radiation scintillation detectors.

Weak Cell Phone Signal Reception Issues & Wireless LAN Problems / RFID Interference

Weak Cellular Phone (including 2G / 3G / 4G LTE) & Wireless Strength Measurements with consulting for correction / mitigation in commercial buildings, residential and multifamily properties with poor coverage, slow data rates and dropped calls for all major telecom and communications carriers including Sprint, T-Mobile, Verizon, AT&T for smartphones, tablets, iPads, etc. Radio Frequency Identification system troubleshooting and interference issues investigated. We also perform FCC RF Compliance surveys for MPE (Maximum Permissible Exposure) including rooftop antenna installations.

Implanted Biomedical Device EMF / EMI Measurement Compliance Surveys and Testing for Patient Safety

Medical Device Compliance Testing (Pacemakers, Implantable Defibrillators, ICD’s etc. – Medtronics, St. Jude Medical, Boston Scientific, Mortara) for individuals returning to work or home after implant surgery to identify potential hazards from AC/DC Magnetic and Electric Fields, Microwaves, RF and general EMI (Electromagnetic Interference).

Hospital Infant Anti-Abduction Security Systems

ScanTech troubleshoots RFID integrated systems designed to protect neonatal care facilities that employ systems such as Hugs by Stanley Healthcare and MyChild by McRoberts Security Technologies.

Electrostatic Discharge (ESD) Testing, Consulting And Evaluation for Commercial, Industrial and Biomedical Companies / Applications / Clients

We have the equipment to determine the sheet resistance of ESD flooring material and if anti-static grounding is working as well as the ability to identify troublesome materials and processes which can cause equipment malfunction and electric shock / fire / explosion hazards. We can also measure relative air ion counts, humidity and the direct DC static voltage on surfaces (positive or negative) up to 30,000 V to determine which objects in the environment may be damaging your static sensitive equipment.

Indoor Air Quality (IAQ) Surveys to Determine Relative Air Cleanliness PM2.5 / PM10 / HEPA Filtration Efficiency / Formaldehyde / VOC / CO2 (Carbon Dioxide) / O2 Oxygen % Concentration & Contamination for Commercial Building and Industrial / Occupational Atmosphere Evaluations with expertise in Nanotoxicology and Medical Environmental Illness Testing

We have time based datalogging air laser analysis available to characterize particulate matter such as small particle contaminants (down to 0.5 microns such as bacteria) and large particle counts (2.5 um and larger) for potential pollen, dust and mold detection which are also known as RSPs. (Respirable Suspended Particles) We can also check for formaldehyde concentrations and VOCs (Volatile Organic Compounds) levels from outgassing materials such as pressed wood flooring or glues and other binders.

Elevated CO2 (carbon dioxide) levels are indicative of Sick Building Syndrome and poor air exchange characteristics in a structure.

New nanomaterials on the market have raised concerns about the potential toxic effects of nanoparticles (such as carbon nanotubes, titanium dioxide, silver NPs, etc.) in particulate, aerosol, aqueous forms and their in-vivo effects.

Commercial, industrial, occupational health and limited residential applications.

http://www.indoorairqualitytestingdallas.com/

OSHA Sound / Noise Level Surveys for Safety Audits

Sound (Commercial) & Industrial Safety field surveys and measurement including for acoustic OSHA sound and STC (Sound Transmission Class) noise levels / ordinances / testing (meeting ANSI & IEC Type 2 standards) to determine compliance and evaluate potential issues with excessive or disruptive noise.

Photometric Glare & Illumination (Lighting Level) Surveys for Safety, OSHA and City Ordinance Compliance

Photometric mapping to identify poor / insufficient / excessive illumination, security camera glare, ATM lighting security assessments, ADA lighting requirements / compliance, and privacy. Many cities have enacted ordinances which limit the amount of light emanating at the property line at night in foot candles. (fc) We can also measure lighting flicker rates which can cause headaches and other performance issues as well as evaluate possible disruption of circadian rhythms which lead to insomnia and lack of restful REM sleep.

Metallurgical Analysis & Consulting

Materials analysis for ferrous / non-ferrous metals / alloys. Tools and tool steel quality evaluations for carbon content. Also magnetic / RF / electric shielding capability, corrosion resistance, heat resistance, degree of temper, quench methods, elasticity, weathering, and electrical quality consulting. Metamaterial composite research for nanotechnology, biomedical, and exotic applications. (graphene, nanoparticles, carbon nanotubes, nanodiamond, etc.) Radioactivity testing for scrap metal or other suspected products.

EMF Meter Phone Apps – Do They Work and/or Indicate Dangerous Conditions?

EMF Meter App for Android Phones and Tablets

EMF Meter App for Android Phones and Tablets (and similar ones for iPhones / iPads) with design based on the Trifield 100XE analog meter

I was recently contacted by a commercial client who was concerned about purchasing office space in McKinney due to a number of factors:

1) The close proximity of some imposing high voltage powerlines directly outside of his office

2) Recent inexplicable computer equipment failures in the office

3) That cute app that you can download onto Android (and probably your iPhone) that measures magnetic fields.

So does this app really work?

DC Magnetic Field Reading (not 60 Hz AC Powerline frequency)

DC Magnetic Field Reading (does NOT read 60 Hz AC Power Line frequencies)

Yes, but NOT in the manner that you think. It works as far as measuring the NATURAL DC magnetic field of the Earth which varies according to locale and the proximity of ferromagnetic building material. But DC means there is no frequency or fluctuation in the field; it is by definition 0 Hertz or 0 cycles per second as opposed to the North American power grid frequency of 60 Hertz.

What is the difference?

Quite a bit.

There is very little evidence that DC magnetic fields are harmful in any way (except higher intensity fields than Earth normal to those with certain biomedical implants such as pacemakers, ICDs, implantable defibrillators, etc.) and in fact there are patents on medical devices which use low level DC fields to speed the healing of broken bones.

But look at the overall reading above showing 834 milliGauss (mG) with the bar graph registering ominously in the red. And speaking of which, the “green – yellow – red” color coding scheme is something I object to in EMF / RF testing instrumentation as it is completely arbitrary from a technical standpoint and induces needless fear-mongering with regard to actual safety levels. It is done partly as a marketing feature to make it look cool, but also as an attempt to give some kind of intuitive user knowledge about the EMFs in the environment, but in fact instills false confidence and infers incorrect information.

While I can give a brief overview of bio-electromagnetics to my clients while consulting, diving into the details is an incredibly complex subject that even a B.S. in Electrical Engineering does not fully prepare you for. You also have to have biomedical knowledge of human and cell physiology (thus, my continuing education and credentials as a biomedical engineer) plus at least some understanding of disease epidemiology and probability / statistics which makes this a truly interdisciplinary field that few understand well.

While the Earth’s magnetic field is typically around 500 – 600 mG, this can be either concentrated or attenuated significantly when inside of the frame of a steel building. What can potentially scare people with this app is that they read about Swiss safety limits of 10 mG, 2.5 mG or even 1 mG and then they assume this reading means they are in some sort of danger. I can guarantee that this meter does not measure anything having to do with health or safety with respect to AC power lines.

The reason for having DC magnetometers built into a smart phone is so that it can relate relative positions of the phone (such as when you turn it on it’s side) with respect to the Earth’s magnetic field and respond accordingly.

It is a cool app to play with and I have it on my phone, but it is not something I would use for a professional EMF inspection, nor would I use it to advise a client on the health, safety or risk conditions of their environment.

EMF & Powerlines – Are the Health and Safety Effects Worth it? A Dallas Inspector’s View

High voltage powerlines, Smart Meters, the cell phone pressed up next to your head… are the effects on your body worth the risk?

I am a professional EMF inspector who has been practicing here in the Dallas – Fort Worth area for nearly the past 15 years and I have some informed thoughts on this subject based on my extensive education, experience and research into this controversial subject.

But before you click away in either fear or skepticism, let me reassure you that my viewpoint on this subject is actually very moderate. I do not demonize the utility companies or the electrification of our society, but neither do I ignore the potential health concerns that many share or the studies that have suggested some possible risks.

North American Life Expectancy Chart Over 100 Years

North American Life Expectancy Chart Over 110 Years

I look at both the pros and the cons of having power on tap in a wide variety of locales. Think back to the turn of the century, (the other century) say about 1900. The average life expectancy of a North American was roughly 47 years – give or take depending on what region of the country, gender, etc.  And in the 130 odd years since Edison switched his first electrical power plant on, the average life expectancy here in the USA has increased by at least 31 years to the age of 78 while the fields we are exposed to daily have gone up by several orders of magnitude. (I recently saw the figure of 16000 times greater)

So if power lines were so harmful, why are we living longer even while our society has become even more electrified?

Obviously, they are not immediately lethal unless you make direct contact in an unfortunate manner, nor are any consistent effects observed at moderate levels. However, I am not saying there is no effect whatsoever. But I feel that many advocates of a “gauss-less” life are missing all of the benefits that electricity brings.

Illuminated roads and buildings at night, hospitals and homes that do not operate by the far more dangerous gas lighting, air conditioning in the sweltering summer, emergency help just 3 digits away…  all of these modern conveniences converge to turn survival from a struggle into something that we can do without much thought.

So why do I perform EMF inspections? Because despite these advantages, people have legitimate concerns and have a right to make informed choices about where they work, live, sleep and spend their leisure time.

I am not a fearmonger, and my goal is to translate the latest findings of science and health research into an understandable context that makes living near powerlines and cell towers less of an unknown.

More to come soon, but for additional information or a survey, feel free to browse the following informative website:

SCANTECH EMF CONSULTING  214.912.4691